The RH5X is a low-cost continuous measurement relative humidity sensor.
#4415
#8811
The RH5X sensor is compatible with all Symphonie series data loggers when equipped with an NRG iPack and either a Symphonie® SCM Card (SCM #3156, used with SymphoniePLUS®3 Data Logger and older) or a Pro Signal Conditioning Module (P-SCM #9132, used with SymphoniePRO® Data Logger when channels 16-19 are unavailable).
The RH5X features a polymer resistor sensor, which provides excellent linearity and sensitivity with fast response time and long-term stability. It mounts to the underside of a shelter box and includes 1.5 m (5’) of cable, a mounting bracket, and one hose clamp.
A calibrated version, the RH5XC, is available. The RH5XC comes with a calibration certificate from a NIST-traceable humidity chamber, providing slope and offset values that can be used to configure your corresponding logger channel.
| RH5X Relative Humidity Sensor (#4415) | RH5XC Relative Humidity Sensor (#8811) | |
|---|---|---|
| Description | ||
| Sensor type | Polymer capacitor humidity sensor | Polymer capacitor humidity sensor |
| Applications |
|
|
| Sensor range | 0 to 100% relative humidity (non-condensing) | 0 to 100% relative humidity (non-condensing) |
| Instrument compatibility | Any Symphonie Data Logger | Any Symphonie Data Logger |
| Output signal | ||
| Signal type | Linear analog voltage | Linear analog voltage |
| Transfer function | % Relative Humidity = Voltage x 20 |
|
| Accuracy |
|
|
| Output signal range | 0 to 5V for 0 to 100% RH, with a load resistance greater than 10 k ohms | 0 to 5V for 0 to 100% RH, with a load resistance greater than 10 k ohms |
| Power requirements | ||
| Supply voltage | 10 V to 30 V DC, 12 V at 2.6 mA typical | 10 V to 30 V DC, 12 V at 2.6 mA typical |
| Installation | ||
| Mounting | Uses a sheet metal bracket with a hose clamp, to be mounted to the tower, under the shelter box | Uses a sheet metal bracket with a hose clamp, to be mounted to the tower, under the shelter box |
| Tools required | 8 mm (5/16 inch) nut driver or wrench | 8 mm (5/16 inch) nut driver or wrench |
| Environmental | ||
| Operating temperature range | -40°C to 70°C (-40°F to 158°F) | -40°C to 70°C (-40°F to 158°F) |
| Operating humidity range | 0 to 100% relative humidity (non-condensing) | 0 to 100% relative humidity (non-condensing) |
| Physical | ||
| Connections |
Wire leads, 3 conductor shielded cable:
|
Wire leads, 3 conductor shielded cable:
|
| Cable length | 1.5 m (5 feet) | 1.5 m (5 feet) |
| Weight | 0.23 kg (0.51 lbs) | 0.23 kg (0.51 lbs) |
| Dimensions | 94 mm (3.7 inches) x 94 mm (3.7 inches) x 56 mm (2.2 inches) enclosure dimensions, without the bracket or shroud | 94 mm (3.7 inches) x 94 mm (3.7 inches) x 56 mm (2.2 inches) enclosure dimensions, without the bracket or shroud |
| Materials | ||
| Cable | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket |
| Enclosure | UV stabilized polycarbonate plastic box with galvanized steel mounting bracket | UV stabilized polycarbonate plastic box with galvanized steel mounting bracket |
For product support, details and FAQS on product please visit : click here